A.relight the boiler immediately to prevent loss of steam pressure
B.relight the fire off the brickwork as the bricks are cherry red
C.purge the furnace of any combustible gases before attempting to relight the fire
D.speed up the feed pump to prevent dry firing when the burner flame is reestablished
您可能感興趣的試卷
你可能感興趣的試題
A.in the event of a flame failure
B.in the event of a stack fire
C.when the water level reach the crown sheet
D.when the feed pump discharge pressure drops to a preset minimum
A.a burned out solenoid in the oil supply valve
B.high temperature excess air
C.incorrectly setting the hot-well dump valve
D.an incorrectly positioned burner snubber realy
A.clean the flame scanner photocell window
B.Inspect and clean all solenoid valves
C.lift the safety valves by hand
D.Inspect for oil or water leaks
A.cold fuel oil
B.low fuel oil pressure
C.low atomizing steam pressure
D.water in the fuel oil
A.adding hydrazine
B.blowing down the boiler
C.adding phenolphthalein
D.adding a sulfite chloride scavenger
最新試題
Which one is NOT the ‘clear grounds’ for a more detailed inspection?()
Using a file without a handle may result in ()
The shipboard oil pollution emergency plan will be invalid after ()
If two A.C.generators are to be operated in parallel, the load is distributed evenly by()
Under MARPOL Code the ship to which it applies has to carry ()
One of the reasons that cause oil flowed from sludge outlet of a self-cleaning separator is()
The Port State Control officer may witness a fire drill carried out by the crew assigned to these duties on the()
When does auxiliary burner of incinerator put into operation? ()Ⅰ. start incinerator when it is coldⅡ. the sludge for dealing with is littleⅢ. the sludge for dealing with is largeⅣ. the water and impurity in sludge are too muchⅤ. the temperature in incinerator is lowⅥ. dealing with little solid rubbish
() is not installed on the main switchboar.
Refrigerant entering the compressor of a refrigeration system should be in which of the following conditions?()